Fast shipping from our warehouse in Nuremberg
Industrial PCs for PAckstation Systems
Mini PCs for smart package lockers.
Compact industrial PCs for the reliable control of modern packing station systems.
Whether it’s a Packstation, a smart locker system, or an automated package delivery system: spo-comm helps you find the right mini-PC for your application—with a compact design, industrial-grade technology, and personalized advice.
01 / It's All About the Application
Technology that fits in your package locker.
Not just any mini-PC. But a solution tailored to the software, installation environment, and operation of your package locker system.
01 / INTEGRATION
Limited installation space
Plan the case dimensions, installation, and cable routing together. That way, not only will the computer fit, but the entire setup will work seamlessly.
02 / OPERATIONS
Reliable Operation
The temperature inside the enclosed housing, heat dissipation, and operating profile determine the appropriate system selection.
03 / CONNECTION
Compatible Interfaces
Connect the display, network, scanner, and control system. The number of devices, the standard, and the system architecture are key factors.
04 / PLANNING
Plannable Series
Coordinate product lifecycle, configuration, and replacement needs early on. Agree on specific availability commitments on a project-by-project basis.
02 / Compare Systems
Mini PCs for various package locker concepts.
Three factors to consider when choosing a system. We’ll determine whether a device is actually a good fit based on your software, peripherals, and installation requirements.
| Selection criterion | BOX x7433EcoCompact Industrial Controller![]() | BRICKUltra: High-Performance Expandability![]() | ONE N100:Compact Entry-Level Model![]() |
|---|---|---|---|
| For Preselection | Compact, fanless system with two Gigabit LAN ports and versatile serial connectivity. | A more powerful, fanless system with two serial interfaces and networking options. | Compact mini-PC with one Gigabit Ethernet port and serial connectivity. |
| Processor | Intel® Atom® x7433RE, 4 cores | Intel® Core™ Ultra 5 125U | Intel® N100, 4 cores, up to 3.4 GHz |
| Dimensions | 120 × 80 × 52 mm; check the measurement sequence before installation | Check on a project-by-project basis using the data sheet | 116 × 107 × 35 mm; check the measurement order before installation |
| Network | 2 × Gigabit LAN | 1 × 2.5-Gigabit LAN · 1 × Gigabit LAN; cellular connectivity optional | 1 × Gigabit LAN |
| USB / COM | 2 × USB 3.2 · 2 × USB 2.0 · 1 × RS-232/422/485 | 4 × USB 3.2 · 2 × RS-232/422/485 | 4 × USB 3.2 · 1 × serial port; check mode before ordering |
| Display | 1 × HDMI 2.0 | 2 × DisplayPort 1.4a | 1 × HDMI 2.0 · 1 × DisplayPort 1.4 |
| Temperature / Cooling | −20 to +70 °C · fanless | −10 to +60 °C · fanless | 0 to +40 °C · fanless |
| Assembly & Production Needs | Coordinate on a project-by-project basis | Project-Specific Coordination | Tailored to the project |
| Go to the product page | Go to the product ↗ | Go to the product ↗ | Go to the product ↗ |
Important for outdoor installations: A temperature range does not replace outdoor approval. Protection against moisture, condensation, and direct sunlight, as well as heat dissipation, must be verified for the entire system. No weather resistance is guaranteed for the models shown.
Tailor installation, power supply, 24/7 suitability, and long-term production requirements to individual needs.
03 / Your Project. Our Support.
More than just hardware.
From the initial request to the customized system configuration: Let’s talk about the technology behind your package locker.
Personal consultation
Work together to align requirements for performance, interfaces, and installation space.
Configuration & Images
Windows IoT customizations, as well as the creation or installation of customer-specific images, upon consultation.
Customization as needed
Additional interfaces, components, or accessories are available upon request and depend on the system.
From Concept to Production
Raise project requirements early on and agree on a suitable configuration for integration and rollout.
04 / Real-World Questions
Ask the right questions before installation.
Technical requirements are as unique as your package locker system. Here are the key points to get you started.
A suitable system is one whose performance, installation dimensions, interfaces, and operating conditions match those of the specific Packstation. The three models compared here serve as a starting point for this evaluation, not as a blanket recommendation.
That depends on the configuration you choose and the actual conditions in the equipment room. The operating profile, cooling, power supply, and maintenance should be evaluated together for your project.
A specified operating temperature range does not constitute a guarantee of weather resistance. Enclosure protection, humidity, condensation, solar radiation, and heat dissipation must be evaluated for the entire system.
Depending on the system and project, the operating system, images, components, and accessories can be customized. We’ll work with you to determine the specific options based on your requirements.
Discuss the project phase and planned quantity with spo-comm. Feasibility, configuration, and terms will be determined on a case-by-case basis.
A potential trial installation can be discussed upon request and under the actual project conditions. It is not guaranteed in all cases.
05 / Working Together to Find the Right Solution
Let's find the right mini PC for your package locker.
Tell us about your application. We’ll match your requirements with the appropriate systems and configuration options.
1
Describe the requirements
Specify the installation space, interfaces, and operating environment.
2
Coordinate System Selection
Work together to clarify performance, configuration, and project requirements.
3
Prepare for Integration
Discuss the appropriate next steps and a possible trial period.
You can also contact spo-comm directly:
info@spo-comm.de
+49 (0) 911 / 23 98 37 – 0
Your form entry has been saved and a unique link has been created which you can access to resume this form.
Enter your email address to receive the link via email. Alternatively, you can copy and save the link below.
Please note, this link should not be shared and will expire in 30 days, afterwards your form entry will be deleted.